Switchgear, control panels, conveyance and harnesses for manufacturers, quoted at 15 weeks.
A manufacturing plant needs power distribution for the building and automation hardware for the line. We build both, in one facility, on one schedule.





Low and medium voltage switchgear, switchboards, automatic transfer switches, power distribution units and power entry units.
UL 508A listed control enclosures with PLC, HMI and motion control built to the platform already running in your plant.
Conveyor systems, elevators and destackers for the lines that move product through the building.
Built to the environment rather than to a generic spec. Routing, strain relief and labeling done for the install.
Cooling for enclosures and process equipment where ambient conditions work against you.

Low and medium voltage switchgear, switchboards, automatic transfer switches, power distribution units and power entry units.

UL 508A listed control enclosures with PLC, HMI and motion control built to the platform already running in your plant.

Conveyor systems, elevators and destackers for the lines that move product through the building.

Built to the environment rather than to a generic spec. Routing, strain relief and labeling done for the install.

Cooling for enclosures and process equipment where ambient conditions work against you.
Fifteen weeks, quoted. The published index for low voltage switchgear is 54 weeks. A shutdown window gets fixed months in advance, and equipment arriving late turns a planned outage into an unplanned one.
One accountable supplier, one schedule and one quality system across power, controls, and cabling.
Built to integrate with what you already run. Our equipment goes in alongside Eaton, Schneider Electric, ABB, Siemens, Legrand and General Electric platforms rather than requiring you to standardize on ours.

AC 208V-600, VDC up to 1000V
AC up to 5000, ADC up to 1000A
Normal up to 100kAIC
Engineered Solution up to 200kAIC
Copper: Tin, Silver
Aluminum: Tin, Silver
Up to 100%
Schneider | ABB | Eaton | LS Electric | Siemens
Available
UL 891 | UL 508A
Factory Tested | Functionality Tested
AC 5kV to 38kV
AC up to 4000A
Normal up to 100kAIC
Copper: Tin, Silver
Aluminum: Tin, Silver
Metal enclosed with fixed breaker
Metal clad with drawout breaker
Utility metering compartments
Schneider | ABB | Eaton | LS Electric | Siemens
Available
IEEE C37.20.7 | UL 1558 | UL 508A
Factory Tested | Functionality Tested
AC 208V to 600V
AC 50kVA to 2MVA
Up to 1200A
Normal up to 100kAIC
Copper: Tin, Silver
Aluminum: Tin, Silver
Up to 200%
Schneider | ABB | Eaton | LS Electric | Siemens
Available
UL 891, UL 508A, UL 1062
80C to 130C temp rise
Aluminum or copper windings
K4 to K20 K-ratings
Up to 7% impedance
Convection cooling
AC 208V-600V
AC up to 800A
Single, Double Back-to-Back, Double Side-by-Side & Quad Arrangement
Normal up to 100kAIC
Copper (Tin, Silver)
Aluminum: (Tin, Silver)
Up to 100%
Schneider | ABB | Eaton | LS Electric | Siemens
Available
UL 891 | UL 508A
Factory Tested | Functionality Tested
You will get back a drawing and a date.