One supplier for power and automation

Switchgear, control panels, conveyance and harnesses for manufacturers, quoted at 15 weeks.

A manufacturing plant needs power distribution for the building and automation hardware for the line. We build both, in one facility, on one schedule.

Talk to an Engineer
Trusted By the Most Demanding Companies on the Planet

What we build for manufacturers

  • Power distribution

    Low and medium voltage switchgear, switchboards, automatic transfer switches, power distribution units and power entry units.

  • Control and automation

    UL 508A listed control enclosures with PLC, HMI and motion control built to the platform already running in your plant.

  • Conveyance and material handling

    Conveyor systems, elevators and destackers for the lines that move product through the building.

  • Cable and harness assemblies

    Built to the environment rather than to a generic spec. Routing, strain relief and labeling done for the install.

  • Thermal management

    Cooling for enclosures and process equipment where ambient conditions work against you.

What we build for manufacturers

  • Power distribution

    Low and medium voltage switchgear, switchboards, automatic transfer switches, power distribution units and power entry units.

  • Control and automation

    UL 508A listed control enclosures with PLC, HMI and motion control built to the platform already running in your plant.

  • Conveyance and material handling

    Conveyor systems, elevators and destackers for the lines that move product through the building.

  • Cable and harness assemblies

    Built to the environment rather than to a generic spec. Routing, strain relief and labeling done for the install.

  • Thermal management

    Cooling for enclosures and process equipment where ambient conditions work against you.

Why plant and engineering teams work with us

Fifteen weeks, quoted. The published index for low voltage switchgear is 54 weeks. A shutdown window gets fixed months in advance, and equipment arriving late turns a planned outage into an unplanned one.

One accountable supplier, one schedule and one quality system across power, controls, and cabling.

Built to integrate with what you already run. Our equipment goes in alongside Eaton, Schneider Electric, ABB, Siemens, Legrand and General Electric platforms rather than requiring you to standardize on ours.

Optima Product Line

Click to learn more

Low Voltage Switchgear & Switchboards

System Voltage

AC 208V-600, VDC up to 1000V

Ampacity Range

AC up to 5000, ADC up to 1000A

Short Circuit Current Rating

Normal up to 100kAIC
Engineered Solution up to 200kAIC

Bus Material - Plated

Copper: Tin, Silver

Aluminum: Tin, Silver

Neutral Rating

Up to 100%

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

UL 891 | UL 508A

Testing

Factory Tested | Functionality Tested

Medium voltage switchgear

System Voltage

AC 5kV to 38kV

Ampacity Range

AC up to 4000A

Short Circuit Current Rating

Normal up to 100kAIC

Bus Material - Plated

Copper: Tin, Silver

Aluminum: Tin, Silver

Enclosure type

Metal enclosed with fixed breaker
Metal clad with drawout breaker
Utility metering compartments

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

IEEE C37.20.7 | UL 1558 | UL 508A

Testing

Factory Tested | Functionality Tested

Power Distribution Units

System Voltage

AC 208V to 600V

Power ratings

AC 50kVA to 2MVA

Panelboard ampacity

Up to 1200A

Short Circuit Current Rating

Normal up to 100kAIC

Bus Material - Plated

Copper: Tin, Silver

Aluminum: Tin, Silver

Neutral Rating

Up to 200%

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

UL 891, UL 508A, UL 1062

Transformer options

80C to 130C temp rise
Aluminum or copper windings
K4 to K20 K-ratings
Up to 7% impedance
Convection cooling

Remote Power Panels (RPPs)

System Voltage

AC 208V-600V

Ampacity Range

AC up to 800A

Configurations Available

Single, Double Back-to-Back, Double Side-by-Side & Quad Arrangement

Short Circuit Current Rating

Normal up to 100kAIC

Bus Material - Plated

Copper (Tin, Silver)

Aluminum: (Tin, Silver)

Neutral Rating

Up to 100%

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

UL 891 | UL 508A

Testing

Factory Tested | Functionality Tested

Engineering and Manufacturing for Seamless Deployment

Lead times as little as 15 weeks
On stocked configurations, with your real date quoted at order
$5 billion in installed capacity
across our 500,000
square foot campus
Made in America
BABA compliant and built in Baltimore
98.6% on time delivery
everything downstream gets scheduled
against that date
99.7% first-pass yield
work that is right the first time does not re-enter the queue
100% functional and quality testing
every unit tested before it ships
Under one roof
engineering, build and test with
nothing subcontracted
ESD and humidity controlled floor
a controlled environment for sensitive assemblies
Certifications

Engineered to the Highest Standards

Send us a spec

You will get back a drawing and a date.

Get In Touch With Our Experts