Optima. Engineered to the Project

Low-voltage switchboards, remote power panels, power distribution units, and medium-voltage switchgear. Built around your specification under UL 891 and UL 508A, factory-tested and functionality-tested before anything ships, in as little as 15 weeks. 

Request a Quote

Optima Product Line

Click to learn more
Certifications

Engineered to the Highest Standards

Low Voltage Switchgear & Switchboards

Engineered for Demanding Applications

Options Available
  • Line Metering
  • Neutral Metering
  • Ground Fault Detection
  • ERMS
  • Overload Protection
  • Short Circuit Prevention
  • NEMA 1, 3R

System Voltage

AC 208V-600V, VDC up to 1000V

Ampacity Range

AC up to 5000A, DC up to 1000A

Short Circuit Current Rating

Normal up to 100kAIC
Engineered Solution up to 200kAIC

Bus Material - Plated

Copper: Tin, Silver

Aluminum: Tin, Silver

Neutral Rating

Up to 100%

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

UL 891 | UL 508A

Testing

Factory Tested | Functionality Tested

Medium Voltage Switchgear

Built for Higher-Demand Infrastructure

Options Available
  • Line Metering
  • Neutral Metering
  • Ground Fault Detection
  • ERMS
  • Overload Protection
  • Short Circuit Prevention

System Voltage

AC 5kV to 38kV

Ampacity Range

AC up to 4000A

Short Circuit Current Rating

Normal up to 100kAIC

Bus Material - Plated

Copper: Tin, Silver

Aluminum: Tin, Silver

Enclosure type

Metal enclosed with fixed breaker
Metal clad with drawout breaker
Utility metering compartments

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

IEEE C37.20.7 | UL 1558 | UL 508A

Testing

Factory Tested | Functionality Tested

Power Distribution Units

Scalable Distribution for High-Demand Systems

Options Available
  • Revenue grade monitoring
  • Line Metering, Neutral Metering
  • Ground Fault Detection
  • Overload Protection
  • Short Circuit Prevention
  • Surge protection device
  • IR viewing
  • Expansion cabinets
  • NEMA 1, 3R

System Voltage

AC 208V to 600V

Power ratings

AC 50kVA to 2MVA

Short Circuit Current Rating

Normal up to 100kAIC

Bus Material - Plated

Copper: Tin, Silver

Aluminum: Tin, Silver

Neutral Rating

Up to 200%

Transformer options

80C to 130C temp rise
Aluminum or copper windings
K4 to K20 K-ratings
Up to 7% impedance
Convection cooling

Panelboard ampacity

Up to 1200A

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

UL 891, UL 508A, UL 1062

Testing

Factory Tested | Functionality Tested

Remote Power Panels (RPPs)

Reliable Distribution for Critical Environments

Options Available
  • Shunt Trips
  • Circuit Metering - Wired
  • Circuit Metering - Wireless
  • Neutral Metering
  • Ground Fault Detection

System Voltage

AC 208V-600V

Ampacity Range

AC up to 800A

Configurations Available

Single, Double Back-to-Back, Double Side-by-Side & Quad Arrangement

Short Circuit Current Rating

Normal up to 100kAIC

Bus Material - Plated

Copper (Tin, Silver)

Aluminum: (Tin, Silver)

Neutral Rating

Up to 100%

Breaker Options

Schneider | ABB | Eaton | LS Electric | Siemens

Seismic Calculations

Available

Standards

UL 891 | UL 508A

Testing

Factory Tested | Functionality Tested

Why Optima

High Capacity
Faster Delivery
Flexible Sourcing
Custom Solutions

Built for Scale